Routing the run…
Routing the run…
Type the number off the device. Get the pinout and terminal functions, fast.
Showing all 6 parts in the single-door catalog.
Mercury
2-door intelligent controller — 2 readers, 8 inputs, 4 Form-C outputs. Current gen (Linux, secure boot).
Mercury
Prior-gen 2-door controller. Same I/O footprint as MP1502; MP can emulate it.
LifeSafety Power
Default. Factory-wired Mercury-ready system: FPO150 150W (12A@12V/6A@24V) + B100 dual-voltage module + C8 lock board (8 fail-safe/secure FAI outputs) + D8P aux (8 × 2.5A Class 2), E4M enclosure with Mercury backplate.
LifeSafety Power
Compact 75W (6A@12V) supply + C8 lock board. The low-door-count alternate to the FPO150 system; same C8 behavior, half the power.
HID
Multi-tech reader. Wiegand or OSDP (RS-485). Watch the 600 mA controller-port budget.
Bosch
Default REX. High-performance PIR, 12–30 VAC/VDC, two Form-C relays (1A@30V), 0.5–64s adjustable latch, selectable fail-safe/secure, door monitor + 85 dB sounder, UL294. Use a diode/bridge rectifier on non-EMF-protected maglocks. Not a primary emergency-egress device.
Before you wire this
Fits the wires ≠ permitted. Pinouts here are a reference, not an approval.
If you are unsure how this door must behave in an alarm or power-loss condition, stop and confirm with your foreman or the AHJ before energizing.